Ara
Toplam kayıt 18, listelenen: 11-18
Comparison of Different Anticoagulation Regimens Regarding Maternal and Fetal Outcomes in Pregnant Patients With Mechanical Prosthetic Heart Valves (from the Multicenter ANATOLIA-PREG Registry)
(Excerpta Medica Inc-Elsevier Science Inc, 2020)
Mechanical prosthetic heart valves (MPHVs) are highly thrombogenic, and a pregnancyinduced procoagulant status increases the risk of MPHV thrombosis. Despite numerous case reports, 2 major registries and meta-analyses/systematic ...
Diagnosis, treatment & management of prosthetic valve thrombosis: the key considerations
(Taylor & Francis Ltd, 2020)
Introduction: Prosthetic heart valve thrombosis is a life-threatening complication after valve replacement surgery. Although subtherapeutic anticoagulation is the main cause, there are many other conventional and esoteric ...
Is fibrinolytic therapy really safe in the treatment of prosthetic valve thrombosis in patients with high INR?
(Wiley, 2021)
To the Editor,
We have recently read with great interest the article by Farzaneh et al.1 entitled “Safety of thrombolytic therapy in patients with prosthetic heart valve thrombosis who have high international normalized ...
Low Dose and Slow/Ultra-Slow Infusion Thrombolytic Therapy Regimens are Effective and Safe in Patients With Prosthetic Valve Thrombosis
(Elsevier Science Inc, 2020)
To the Editor,We have recently read with great interest the article by Milneet al. entitled‘Management and outcomes of prosthetic valvethrombosis. An Australian case series from the NorthernTerritory’[1].
The relationship between incomplete surgical obliteration of the left atrial appendage and thromboembolic events after mitral valve surgery (from the ISOLATE Registry)
(Springer, 2021)
Left atrial appendage (LAA) is a common site of thrombus formation especially in patients with atrial fibrillation (AF). Complete surgical LAA closure (cSLC) is the surgical aim, however incomplete surgical LAA closure ...
The value of brain natriuretic peptide in the prosthetic valve thrombosis
(Lippincott Williams & Wilkins, 2020)
We aimed to investigate how prosthetic valve thrombosis (PVT) affects brain natriuretic peptide (BNP) levels and how BNP changes following thrombolytic therapy. The study included 70 consecutive patients with left-sided ...
Normal reference values for mechanical mitral prosthetic valve inner diameters and areas assessed by two-dimensional and real-time three-dimensional transesophageal echocardiography
(Springer, 2021)
It was previously observed that two dimensional (2D) Doppler derived and real-time three-dimensional (RT-3D) directly measured valve areas were smaller than reported manufacturer sizes. It may be helpful to obtain the ...
Characteristic localization patterns of thrombus on various brands of bileaflet mitral mechanical heart valves as assessed by three-dimensional transesophageal echocardiography and their relationship with thromboembolism
(Springer, 2021)
Three-dimensional transesophageal echocardiography (3D-TEE) provides detailed images of prosthetic valve thrombosis (PVT). However, data regarding PVT localization patterns based on 3D-TEE and their association with clinical ...