Ara
Toplam kayıt 27, listelenen: 11-20
Intermittent malfunction and regurgitation of a mitral prosthetic valve due to entrapment by a residual subvalvular apparatus
(Blackwell Publishing Inc., 2018)
Intermittent malfunction is a rare but potentially serious complication of prosthetic heart valve (PHV) replacement. It may be observed in both mitral and aortic valve prosthesis and may lead to either paroxysmal obstruction ...
Evaluation of the potential predictors of embolism in patients with left atrial myxoma
(Blackwell Publishing Inc., 2019)
Introduction: Cardiac myxomas are the most common primary intracardiac tumors. Although myxomas are histologically benign, they are potentially dangerous due to potential risk of systemic and cerebral embolism. In this ...
Comparison of different anticoagulation regimens in pregnant patients with mechanical prosthetic heart valves
(Oxford Univ Press, 2017)
[Abstract Not Available]
Noninvasive diagnostic tools available for discrimination pannus from thrombus in patients with prosthetic valve dysfunction
(Blackwell Publishing Inc., 2019)
We have recently read with great interest the article by Barroso Freitas‐Ferraz et al1 entitled “Prosthetic aortic valve thrombosis: To fibrinolyse or not to fibrinolyse? That is the question!”. The authors reported a case ...
Relationship between heparanase levels and prosthetic valve thrombosis: clinical implications
(Oxford Univ Press, 2017)
[Abstract Not Available]
Assessment of the relationship between C-reactive protein-to-albumin ratio and slow coronary flow in patients with stable angina pectoris
(Lippincott Williams & Wilkins, 2019)
Background The relationship between severity of coronary artery disease and inflammatory parameters has been previously demonstrated. However, there is a lack of data regarding the role of C-reactive protein-to-albumin ...
The mortal cause of sudden ECG changes in patients with chronic aortic insufficiency: Aortic dissection
(Akademiai Kiado Rt., 2019)
The symptoms of aortic dissection (AD) may be highly variable and may mimic other much common conditions. Thus, a high index of suspicion should be maintaned, especially when the risk factors for AD are present or signs ...
Identification of mechanical prosthetic heart valves based on distinctive cinefluoroscopic and echocardiographic markers
(Sage Publications Ltd, 2019)
The past 65 years have witnessed remarkable progress in the development of safe, hemodynamically favorable mechanical heart valves. Today, there are a large number and variety of prostheses in use and many prostheses have ...
The Relationship Between HbA1c Level and Beck Depression Scale in Patients with Heart Failure with Type 2 Diabetes Mellitus
(2018)
Introduction: Multiple studies have shown the relationship between heart failure (HF) and development of depression. Several studies have demonstrated worse perception of quality of life among patients with type 2 diabetes ...
Normal reference values for mechanical mitral prosthetic valve inner diameters and areas assessed by two-dimensional and real-time three-dimensional transesophageal echocardiography
(Springer, 2021)
It was previously observed that two dimensional (2D) Doppler derived and real-time three-dimensional (RT-3D) directly measured valve areas were smaller than reported manufacturer sizes. It may be helpful to obtain the ...