Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDalkız, Mehmet
dc.contributor.authorArslan, Demet
dc.contributor.authorTunçdemir, Ali Rıza
dc.contributor.authorBilgin, M. Selim
dc.contributor.authorAykul, Halil
dc.date.accessioned2019-05-13T09:03:20Z
dc.date.available2019-05-13T09:03:20Z
dc.date.issued2012
dc.identifier.citationDalkız, M., Arslan, D., Tuncdemir, A. R., Bilgin, M. S., Aykul, H. (2012). Effect of different palatal vault shapes on the dimensional stability of glass fiber-reinforced heat-polymerized acrylic resin denture base material. European journal of dentistry, 6(1), 70.en_US
dc.identifier.issn1305-7456
dc.identifier.urihttps://hdl.handle.net/11491/1453
dc.description.abstractObjective: The aim of this study was to determine the effect of different palatal vault shapes on the dimensional stability of a glass fiber reinforced heat polymerized acrylic resin denture base material. Methods: Three edentulous maxilla with shallow, deep and medium shaped palatal vaults were selected and elastomeric impressions were obtained. A maxillary cast with four reference points (A, B, C, and D) was prepared to serve as control. Point (A) was marked in the anterior midline of the edentulous ridge in the incisive papillary region, points (B) and (C) were marked in the right and left posterior midlines of the edentulous ridge in the second molar regions, and point (D) was marked in the posterior palatal midline near the fovea palatina media (Figure 2). To determine linear dimensional changes, distances between four reference points (A-B, A-C, A-D and B-C) were initially measured with a metal gauge accurate within 0.1 mm under a binocular stereo light microscope and data (mm) were recorded. Results:No significant difference of interfacial distance was found in sagittal and frontal sections measured 24 h after polymerization and after 30 days of water storage in any of experimental groups (P>.05). Significant difference of linear dimension were found in all experimental groups (P<.01) between measurements made 24 h after polymerization of specimens and 30 days after water storage. Conclusion: Palatal vault shape and fiber impregnation into the acrylic resin bases did not affect the magnitude of interfacial gaps between the bases and the stone cast surfaces.en_US
dc.language.isoeng
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAcrylic Resin Denture Baseen_US
dc.subjectDenture Reinforcing Fiberen_US
dc.subjectDimensional Stabilityen_US
dc.subjectPalatal Vault Shapeen_US
dc.subjectPolymerizationen_US
dc.titleEffect of different palatal vault shapes on the dimensional stability of glass fiberreinforced heat-polymerized acrylic resin denture base materialen_US
dc.typearticleen_US
dc.relation.journalEuropean Journal of Dentistryen_US
dc.departmentHitit Üniversitesi, Mühendislik Fakültesi, Makine Mühendisliği Bölümüen_US
dc.identifier.volume6en_US
dc.identifier.issue1en_US
dc.identifier.startpage70en_US
dc.identifier.endpage78en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster