Ara
Toplam kayıt 14, listelenen: 1-10
Irreversibility analysis of a vapor compression cascade refrigeration cycle
(2009)
Hydrocarbon based energy sources such as coal, oil and natural gas have been diminishing in an increasing speed. Instead of finding alternative energy sources, we have to use the available sources more effectively. By means ...
Energy and exergy analysis of an air conditioning system using the mixture of outdoor and return air
(2012)
Energy and exergy analysis of the air conditioning systems employing the mixture of outdoor and return air (ACOR) are presented. The equations of heat transfer rate and exergy destruction are developed for ACOR according ...
Determination of noise level of a gas-fired pulse combustor
(2007)
Experimental determination of noise level of a Helmholtz type gas-fired pulse combustor is presented. During the tests, the tail pipe length was varied from 1.9 m to 1.3 m by 10 cm intervals. Noise level measurements were ...
Performance investigation of an eight cylinder gasoline engine
(American Society of Mechanical Engineers (ASME), 2014)
Performance investigation of a Chevrolet 5.7, eight cylinder gasoline engine is experimentally carried out at laboratuary conditions by means of the special softwares called "NetDyn" and "WinDyn". This experimental work ...
Investigation of irreversibilities in the compression process for alternative refrigerants in a vapor compression refrigeration cycle
(2008)
Irreversibility analyses during compression process are presented for some refrigerants namely, R290, R134a, R12, R22, and R152a in a vapor compression refrigeration cycle. The effects of evaporator temperature, condenser ...
Acoustic analysis of a liquefied petroleum gas-fired pulse combustor
(2008)
Experimental investigation of acoustic characteristics of a Helmholtz type liquefied petroleum gas-fired pulse combustor is presented. In the experiments, the length of the tail pipe was changed from 1.9 m to 1.3 m by 10 ...
Exergy analysis of R1234yf and R1234ze as R134a replacements in a two evaporator vapour compression refrigeration system
(Elsevier Ltd, 2015)
Exergy analysis is a useful way for determining the real thermodynamic losses and optimising environmental and economic performance in the systems such as vapour compression refrigeration systems. The present study deals ...
Irreversibility analysis of a two-evaporator vapour compression refrigeration system
(Inderscience Enterprises Ltd., 2015)
In this study, irreversibility analysis of a two-evaporator vapour compression refrigeration system under the influence of superheating and subcooling effects was carried out. The thermodynamic properties of the refrigerants ...
Investigation of the component exergy efficiencies of a two stage vapour compression cycle
(Inderscience Enterprises Ltd., 2018)
The exergy efficiencies of the components (compressor I and II, condenser, evaporator and flash tank) of a two stage vapour compression refrigeration cycle were analysed with respect to evaporator and condenser temperatures ...
Irreversibility analysis of a compression refrigeration cycle using natural refrigerants for a sustainable future
(2012)
Irreversibility analyses of R290, R717, R718 and R744 are carried out in a compression refrigeration cycle. The effects of evaporator temperature, condenser temperature and isentropic efficiency on the irreversibility of ...