Ara
Toplam kayıt 1307, listelenen: 751-760
ST-segment elevation myocardial infarction possibly caused by thromboembolism from left atrial appendage thrombus after incomplete surgical ligation
(Blackwell Publishing Inc., 2018)
Coronary embolism (CE) is the underlying cause of 3% of acute coronary syndromes but is frequently overlooked in the differential diagnoses of acute coronary syndromes. The CE may be direct (left sided from the native or ...
Multimodality imaging of a left ventricular aneurysm in a patient with normal coronary arteries: Unusual localization
(Blackwell Publishing Inc., 2017)
Left ventricular aneurysm (LVA) is rare but potentially fatal complication of myocardial infarction. It has been strictly defined as a distinct area of abnormal left ventricular diastolic contour with systolic dyskinesia ...
Thrombus formation in the interrupted segment of the aorta
(Blackwell Publishing Inc., 2017)
Interrupted aorta is a very rare heart defect in which there is a gap between the ascending and the descending thoracic aorta. It is usually associated with other cardiac anomalies, including ventricular septal defect, ...
Intermittent malfunction and regurgitation of a mitral prosthetic valve due to entrapment by a residual subvalvular apparatus
(Blackwell Publishing Inc., 2018)
Intermittent malfunction is a rare but potentially serious complication of prosthetic heart valve (PHV) replacement. It may be observed in both mitral and aortic valve prosthesis and may lead to either paroxysmal obstruction ...
Use of a superficial femoral artery autograft as a femoral vein replacement
(Elsevier Inc., 2015)
Posttraumatic arteriovenous fistulas (AVFs) are common complications of vascular penetrating trauma. Here we present a case of a 59-year-old woman who had a history of gunshot injury 42 years ago causing AVF between ...
A novel suture technique for distal aorta-graft anastomosis in aortic aneurysm repair surgery: Diagonal basting stitch
(Elsevier Inc., 2015)
We describe a novel suture technique of distal anastomosis between the graft and the aorta in ascending aortic aneurysm repair surgery. In this technique, the aortic graft is positioned inside the distal aortic lumen with ...
Groin swelling in a four-year-old boy: Primary great saphenous vein aneurysm
(Elsevier Inc., 2015)
Primary venous aneurysm, especially in pediatric population, is a very rare clinical entity. We report a case of primary great saphenous vein aneurysm in a 4-year-old boy. He was initially suspected of suffering from ...
Prognostic factors in endometrial clear cell carcinoma
(Springer Verlag, 2017)
Objective: To document the experience regarding patients treated for endometrial clear cell carcinoma (ECCC), with reference to clinical, biochemical, histopathologic, and prognostic features. Material and methods: Twenty-six ...
How to perform and manage low-dose and slow/ultra-slow tissue type plasminogen activator infusion regimens in patients with prosthetic valve thrombosis
(Springer New York LLC, 2018)
Over the last two decades, thrombolytic therapy (TT) has become an alternative to surgery as a first-line therapy in patients with thrombosed mechanical valves [1, 2, 3]. In TROIA Trial, low dose (25 mg)—slow infusion (6 ...
What is the importance of real-time three dimensional transesophageal echocardiography and time in therapeutic range in patients with prosthetic valve thrombosis?
(Springer New York LLC, 2018)
We have recently read with great interest the article reported by Cınar et al. which was published in the last issue of the Journal of Thrombosis and Thrombolysis [1]. We appreciate the authors for their report describing ...