Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDiken, Adem İlkay
dc.contributor.authorYalçınkaya, Adnan
dc.contributor.authorHanedan, Onur
dc.contributor.authorGünertem, Orhan Eren
dc.contributor.authorDemir, Emre
dc.contributor.authorErol, Emir
dc.date.accessioned2019-05-10T09:39:06Z
dc.date.available2019-05-10T09:39:06Z
dc.date.issued2017
dc.identifier.citationDiken, A. I., Yalcinkaya, A., Hanedan, O., Gunertem, E., Demir, E., & Erol, E. (2017). Effect of tandem lesions on haemodynamic parameters: an experimental study. Kardiologia polska, 75(12), 1315-1323.en_US
dc.identifier.issn0022-9032
dc.identifier.urihttps://doi.org/10.5603/KP.a2017.0163
dc.identifier.urihttps://hdl.handle.net/11491/609
dc.description.abstractBackground: The morphology and extensity of the stenotic lesion is crucial as well as the obstruction ratio. It is well known that the complexity of lesions has a direct impact on endovascular treatment (PTCA/stent); however, the arrangement of the lesions is underestimated and not well studied. Aim: We sought to evaluate the haemodynamic effects of different stenotic lesion models and arrangements in vitro. Methods: Vascular circulation was simulated in vitro. Oxygenator, tubing set, polytetrahidroflouroethylene synthetic graft, pressure and flow rate, sensors were used to build the simulation model. Measurements of isolated short, isolated long, identical stenotic tandem short, identical stenotic tandem long, sub-critical long, and critical short lesion combinations were performed and haemodynamic parameters were recorded. Results: Tandem lesions were more likely to result in critical stenosis comparing single lesions with the same obstruction ratio. This difference became more significant as the obstruction ratio was raised. Tandem long lesions also resulted in more critical stenosis than tandem short lesions. It can be claimed that tandem lesions can result in more flow restriction with reference to single lesions with the same stenotic ratio. Contrary to expectations, tandem short lesions were found to be more stenotic compared with the same degree long individual lesions. Conclusions: It is effortless to give the decision for simple, discrete and individual lesions, while the ideal decision for long and complicated lesions may remain unclear. Even if these "grey zone" lesions are considered non-critical while investigating them one by one, it must be kept in mind that the overall stenotic effect of these lesions may lead to more haemodynamic impairment. © Polskie Towarzystwo Kardiologiczne 2017.en_US
dc.language.isoeng
dc.publisherVia Medicaen_US
dc.relation.isversionof10.5603/KP.a2017.0163en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCirculation Physiologyen_US
dc.subjectFractional Flow Reserveen_US
dc.subjectTandem Vascular Lesionen_US
dc.titleEffect of tandem lesions on haemodynamic parameters: An experimental studyen_US
dc.typearticleen_US
dc.relation.journalKardiologia Polskaen_US
dc.departmentHitit Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.authorid0000-0002-8782-7603en_US
dc.authorid0000-0002-3834-3864en_US
dc.identifier.volume75en_US
dc.identifier.issue12en_US
dc.identifier.startpage1315en_US
dc.identifier.endpage1323en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster