Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.advisorKoçak, Özgür
dc.contributor.authorEsen, Kamil
dc.date.accessioned2021-11-01T14:48:18Z
dc.date.available2021-11-01T14:48:18Z
dc.date.issued2021
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=9MiDp3x86xrwjpi5-14w-b8lLj607uRXBjjE7HbPTYWhtFlsulr2AepYsw8c06-V
dc.identifier.urihttps://hdl.handle.net/11491/6152
dc.descriptionYÖK ID: 661391en_US
dc.description.abstractAmaç: Kontrasepsiyon amacıyla kullanılan rahim içi araçların over rezervi üzerindeki etkisini araştırmak ve olumlu veya olumsuz yönlerini ortaya çıkarmak. Gereç ve Yöntem: 18-49 yaş aralığında daha önceden doğum yapmış ve kontrasepsiyon amaçlı bakırlı rahim içi araç kullanmayı tercih eden ve erken foliküler fazdaki ilk 45 kişi onamları alındıktan sonra çalışmaya dahil edilmiştir. Rahim içi araç uygulanmadan önce AMH (Anti Müllerian Hormon) , INHB (İnhibin B), FSH (Folikül Stimülan Hormon) ve E2 (Estradiol) için kan örneği alındı, yaş, adet düzeni, özgeçmiş gibi özellikler sorgulandı. Rahim içi araç uygulandıktan sonra antral folikül sayısı (AFS) için ve rahim içi aracın lokalizasyonu için transvajinal ultrasonografi yapıldı. Aynı işlemler 3 ay sonra tekrarlandı ve başvuru anındaki verilerle kıyaslandı. Serum örnekleri çalışılacağı güne kadar -80 o C'de saklandı. FSH ve E2 seviyelerini belirlemek için 'competitive enzyme linked immune sorbent assay' yöntemi, AMH ve INHB seviyelerinin ölçümünde ise 'the sandwich enzyme linked immune sorbent assay' yöntemi kullanıldı. Bulgular: Rahim içi araç uygulama anındaki (0. ay) ve kontrol anındaki (3. ay) veriler karşılaştırıldığında AMH düzeyindeki azalma, E2 düzeyindeki artma istatistiksel olarak anlamlı bulunmuştur. FSH, INHB düzeylerinde ise istatistiksel olarak anlamlı fark bulunamamıştır. AFS'de ki azalma anlamlı tespit edilmiştir. Adet düzeni sorgulanan gönüllülerin siklus süresinde ve günlük değiştirilen ped sayısında anlamlı bir değişiklik bulunmamasına rağmen kanama süresinin istatistiksel olarak anlamlı bir şekilde arttığı görülmüştür. Sonuç: Kontrasepsiyon amaçlı kullanılan bakırlı rahim içi araçlar (RİA) AMH ve AFS'de azalma meydana getiriyor. Bu da bakırlı RİA'ların erken dönemde over rezervini azalttığını gösterir.en_US
dc.description.abstractAim: To investigate the effect of intrauterine devices used for contraception on ovarian reserve and to detect their positive or negative affects. Materials and Methods: The first 45 volunteers in the early follicular phase who gave birth before and who preferred to use a copper-containing intrauterine device for contraception were included in the study after obtaining their informed consents. Before the intrauterine device was applied, blood samples were taken for AMH, INHB, FSH and E2, and demographic data such as age, menstrual cycles and anamnesis were taken. After the intrauterine device was applied, transvaginal ultrasonography was performed for antral follicle count (AFS) and to check the localization of the intrauterine device. The same procedures were repeated 3 months later and compared with the data at the time of application. Serum samples were stored at -80 o C until the day of study. The "competitive enzyme linked immune sorbent assay" method was used to determine FSH and E2 levels, and the "the sandwich enzyme linked immune sorbent assay" method was used to measure AMH and INHB levels. Results: When the data at the time of intrauterine device application (0 month) and control (3rd month) were compared, the decrease in the AMH level and the increase in the E2 level were found to be statistically significant. There was no statistically significant difference in FSH and INHB levels. The decrease in AFS was found to be significant. Although there was no significant change in the cycle duration and the number of pads changed per day. It is observed that the bleeding time increased statistically significant. Conclusion: Copper intrauterine devices (IUD) used for contraception and may decrease in AMH and AFS. This shows that copper IUDs have an effect on ovarian reserve tests in the early period.en_US
dc.language.isoturen_US
dc.publisherHitit Üniversitesien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectKadın Hastalıkları ve Doğumen_US
dc.subjectObstetrics and Gynecologyen_US
dc.subjectAMHen_US
dc.subjectİNHBen_US
dc.subjectFSHen_US
dc.subjectE2en_US
dc.subjectAFSen_US
dc.subjectAntimüllerian hormonen_US
dc.subjectAntimullerian hormoneen_US
dc.subjectEstradiol =en_US
dc.subjectFolikül uyarıcı hormonen_US
dc.subjectFollicle stimulating hormoneen_US
dc.subjectKontraseptif cihazlaren_US
dc.subjectContraceptive devicesen_US
dc.subjectOver fonksiyon testlerien_US
dc.subjectOvarian function testsen_US
dc.subjectRahim içi araçlar =en_US
dc.subjectİnhibinleren_US
dc.subjectInhibinsen_US
dc.subjectAMHen_US
dc.subjectINHBen_US
dc.subjectFSHen_US
dc.subjectE2en_US
dc.subjectAFSen_US
dc.titleRahimiçi araçların over rezerv testleri üzerine etkisien_US
dc.title.alternativeThe effect of intrauteri?ne devi?ces on ovari?an reserve testsen_US
dc.typespecialistThesisen_US
dc.departmentHitit Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Kadın Hastalıkları ve Doğum Anabilim Dalıen_US
dc.identifier.startpage1en_US
dc.identifier.endpage83en_US
dc.relation.publicationcategoryTezen_US
dc.contributor.institutionauthorEsen, Kamil


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster