Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKaradaş Bakırhan, Nurgül
dc.contributor.authorÖzkan, Sibel Ayşıl
dc.date.accessioned2019-05-10T09:39:17Z
dc.date.available2019-05-10T09:39:17Z
dc.date.issued2014
dc.identifier.citationKaradas, N., & Ozkan, S. A. (2014). Electrochemical preparation of sodium dodecylsulfate doped over-oxidized polypyrrole/multi-walled carbon nanotube composite on glassy carbon electrode and its application on sensitive and selective determination of anticancer drug: Pemetrexed. Talanta, 119, 248-254.en_US
dc.identifier.issn0039-9140
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2013.10.065
dc.identifier.urihttps://hdl.handle.net/11491/659
dc.description.abstractElectrochemical oxidation of pemetrexed (PMX) was studied on bare, carboxylic acid functionalized multi-walled carbon nanotubes and over-oxidized polypyrrole modified (oo-PPy/MWCNTs-COOH/GCE) glassy carbon electrodes by cyclic and adsorptive stripping differential pulse voltammetric techniques. The oo-PPy/MWCNTs-COOH/GCE is very sensitive to the oxidation of PMX. The results proved that the over-oxidation of the PPy film gave a negative charge density on porous layer that improved the adsorption for PMX. The effects of pH, concentrations of MWCNTs and monomer, the number of cycles for the electropolymerization and the scan rate for sensor preparation were optimized. The MWCNTs-COOH and oo-PPy based sensor showed an excellent recognition capacity toward PMX. The linear responses have been obtained in the range from 8.00×10 -7 M to 1.00×10 -4 M with 2.04×10 -7 M detection limit for the bare GCE and from 1.00×10 -8 M to 1.00×10 -7 M with 3.28×10 -9 M detection limit for the modified GCE. The oxidation of PMX was controlled by the adsorption process on both types of electrode surfaces. The proposed methods were compared with the literature on UV spectrophotometric assay, which was carried out at an absorption maximum of 225 nm. The proposed method and the designed sensors have been successfully applied for the determination of PMX in pharmaceuticals. © 2013 Elsevier B.V. All rights reserved.en_US
dc.language.isoeng
dc.publisherElsevier B.V.en_US
dc.relation.isversionof10.1016/j.talanta.2013.10.065en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectConductive Polymersen_US
dc.subjectMulti Walled Carbon Nanotubesen_US
dc.subjectPemetrexeden_US
dc.subjectVoltammetryen_US
dc.titleElectrochemical preparation of sodium dodecylsulfate doped over-oxidized polypyrrole/multi-walled carbon nanotube composite on glassy carbon electrode and its application on sensitive and selective determination of anticancer drug: Pemetrexeden_US
dc.typearticleen_US
dc.relation.journalTalantaen_US
dc.departmentHitit Üniversitesi, Fen Edebiyat Fakültesi, Kimya Bölümüen_US
dc.identifier.volume119en_US
dc.identifier.startpage248en_US
dc.identifier.endpage254en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster