Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorCevher, Selim
dc.contributor.authorSahin, Tayfun
dc.date.accessioned2021-11-01T15:03:04Z
dc.date.available2021-11-01T15:03:04Z
dc.date.issued2020
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.urihttps://doi.org/10.1007/s10792-020-01625-9
dc.identifier.urihttps://hdl.handle.net/11491/6954
dc.description.abstractPurpose To compare the ciliary muscle thickness (CMT) of the normal fellow eye to that of the amblyopic eye using ultrasound biomicroscopy (UBM) in patients with unilateral anisometropic amblyopia. Methods Thirty patients with unilateral anisometropic amblyopia were involved. The patients were divided into two groups: 19 hyperopic and 11 myopic. Axial length (AL) was measured with optic biometry and anterior chamber depth (ACD), iris area, and CMT were measured with UBM. Results The mean age was 34.10 +/- 6.61 years. The mean spherical difference between two eyes was 2.59 diopter (D) in hyperopic patients and 3.77D in myopic patients. In the hyperopic patients, nasal CMT1(nCMT), temporal CMT1(tCMT), tCMT2, and tCMT3 values were statistically thinner in amblyopic eyes than healthy eyes (p = 0.036,p = 0.003,p = 0.023,p = 0.005, respectively). ACD values were statistically lower in amblyopic eyes (2.78 +/- 0.26 mm) than healthy eyes (2.90 +/- 0.21 mm) (p < 0.001). In the myopic patients, nCMT1, nCMT2, nCMT3, tCMT1, tCMT2, and tCMT3 values were statistically thicker in amblyopic eyes than healthy eyes (p = 0.003,p = 0.003,p = 0.005,p = 0.003,p = 0.003,p = 0.019, respectively). ACD values were statistically higher in amblyopic eyes (3.20 +/- 0.30 mm) than healthy eyes (3.06 +/- 0.29 mm) (p = 0.004). Also, there was no significant difference in the iris area between the amblyopic and normal eyes of the myopic and hyperopic patients (p > 0.05). Conclusions Amblyopic eyes in patients with unilateral myopic anisometropia have thicker CMT and deeper ACD than healthy eyes. Conversely, amblyopic eyes in patients with unilateral hyperopic anisometropia have thinner CMT and shorter ACD than healthy eyes. There is a positive correlation between AL and CMT.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.ispartofInternational Ophthalmologyen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCiliary muscle thicknessen_US
dc.subjectAnisometropic amblyopiaen_US
dc.subjectUltrasound biomicroscopyen_US
dc.titleDoes anisometropia affect the ciliary muscle thickness? An ultrasound biomicroscopy studyen_US
dc.typearticleen_US
dc.department[Belirlenecek]en_US
dc.authoridSAHIN, TAYFUN / 0000-0003-2319-0807
dc.identifier.volume40en_US
dc.identifier.issue12en_US
dc.identifier.startpage3393en_US
dc.identifier.endpage3402en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.department-temp[Cevher, Selim; Sahin, Tayfun] Hitit Univ, Fac Med, Dept Ophthalmol, Cayiri Cd 45 A, TR-019040 Corum Merkez, Corum, Turkeyen_US
dc.contributor.institutionauthor[Belirlenecek]
dc.identifier.doi10.1007/s10792-020-01625-9
dc.authorwosidSAHIN, TAYFUN / ABI-3692-2020
dc.description.wospublicationidWOS:000580440600004en_US
dc.description.scopuspublicationid2-s2.0-85092783609en_US
dc.description.pubmedpublicationidPubMed: 33083933en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster