Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorŞevik, Seyfi
dc.contributor.authorÖzdilli, Özgür
dc.date.accessioned2021-11-01T15:05:25Z
dc.date.available2021-11-01T15:05:25Z
dc.date.issued2021
dc.identifier.issn1290-0729
dc.identifier.issn1778-4166
dc.identifier.urihttps://doi.org/10.1016/j.ijthermalsci.2021.107101
dc.identifier.urihttps://hdl.handle.net/11491/7269
dc.description.abstractIn this study, splayed effects on the thermal performance of standard cross-cut heat sink (S-CCHS), fixed-array splayed (FAS-CCHS), and full splayed (FS-CCHS) under natural and forced conditions are studied experimentally and numerically. For this purpose, variable parameters such as splayed ratio, different powers of LEDs, natural and forced conditions, and blowing direction have been studied. The results showed that the thermal performance is significantly impacted by the spread position of the fins, blowing direction, natural and forced conditions of the CCHS but is not very sensitive to LEDs' powers. The results show that the full splayed heat sink occupies the highest physical volume, thus, provides the highest thermal performance by efficiently dissipating heat compared to other heat sinks designs. Experimental and numerical results show that the full splayed effect provides 5.46% and 2.59% lower junction temperature in natural and forced, respectively. Also, FS-CCHS achieved a 7.09% reduction in thermal resistance at natural convection 3 W and a 2.62% reduction at 10 W, respectively, compared to the flat fins and the fixed array wide fin heat sink. For this study, while the most suitable flow direction was determined as push, the most suitable orientation was found to be upward, and the splayed impact was also beneficial.en_US
dc.language.isoengen_US
dc.publisherElsevier France-Editions Scientifiques Medicales Elsevieren_US
dc.relation.ispartofInternational Journal Of Thermal Sciencesen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHeat sinken_US
dc.subjectCross-cut finen_US
dc.subjectSplayeden_US
dc.subjectExperimental and numerical analysisen_US
dc.subjectHeat dissipationen_US
dc.subjectThermal performanceen_US
dc.titleExperimental and numerical analysis of the splay impact on the performance of splayed cross-cut fin heat sinken_US
dc.typearticleen_US
dc.department[Belirlenecek]en_US
dc.identifier.volume170en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.department-temp[Sevik, Seyfi] Hitit Univ, Vocat Sch Tech Sci Elect & Energy, Corum, Turkey; [Ozdilli, Ozgur] Hitit Univ, Vocat Sch Tech Sci Machinery & Met Tech, Corum, Turkeyen_US
dc.contributor.institutionauthorŞevik, Seyfi
dc.contributor.institutionauthorÖzdilli, Özgür
dc.identifier.doi10.1016/j.ijthermalsci.2021.107101
dc.description.wospublicationidWOS:000685519200003en_US
dc.description.scopuspublicationid2-s2.0-85107931189en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster