Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorSevik, Seyfi
dc.contributor.authorKocer, Abdulkadir
dc.contributor.authorInce, Huseyin
dc.contributor.authorTombus, Fazli Engin
dc.date.accessioned2021-11-01T15:05:34Z
dc.date.available2021-11-01T15:05:34Z
dc.date.issued2021
dc.identifier.issn1745-2007
dc.identifier.issn1752-7589
dc.identifier.urihttps://doi.org/10.1080/17452007.2021.1926899
dc.identifier.urihttps://hdl.handle.net/11491/7326
dc.description.abstractThis study aims to determine the optimum tilt angle of the solar collector or PV for the province of corum, Turkey, and evaluate the existing 2019 building stocks in ten neighborhoods in terms of solar potential. The optimum collector tilt angle was obtained between 15 degrees and 56 degrees for six-month periods, it was calculated as 63 degrees, 24 degrees, 7 degrees, and 49 degrees for seasonal (winter, spring, summer, autumn) periods, respectively, and according to these values, the optimum solar radiation values were found for tilt angles. The annual optimum tilt angle for corum was found to be 34 degrees +/- 1; however, it was calculated that the optimum tilt angles during the year could vary between 1 degrees and 67 degrees. These results show that positioning the solar collectors/PVs at the optimum tilt angle, adjusting the tilt angle once a month or at least twice a year, or using solar tracking systems provide significant efficiency gains for optimum benefit. Based on the calculations made with azimuth angles, it was determined that 60% of the sampling buildings were positioned to benefit from sunlight during the day, and 10% of them are partially positioned, and thus, these buildings contribute to decarbonization. For this reason, it has been determined that the existing building stocks in corum province are highly suitable for low-cost roof installations and the construction of future buildings according to the locations determined in this study will increase thermal comfort. Although this study is mainly focused on local interest, it can be adapted to the general.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Ltden_US
dc.relation.ispartofArchitectural Engineering And Design Managementen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectSolar collectoren_US
dc.subjectPV panelen_US
dc.subjectoptimum tilt angleen_US
dc.subjectbuilding stock positioningen_US
dc.subjectsolar potentialen_US
dc.titleDetermination of optimum tilt angle of the solar collector and evaluation of the position of the existing buildings in terms of solar potentialen_US
dc.typearticleen_US
dc.department[Belirlenecek]en_US
dc.authoridSevik, Seyfi / 0000-0003-4063-0456
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.department-temp[Sevik, Seyfi] Hitit Univ, Tech Sci Vocat Sch, Dept Elect & Energy, Corum, Turkey; [Kocer, Abdulkadir] Akdeniz Univ, Vocat Sch Tech Sci, Dept Elect & Energy, Antalya, Turkey; [Ince, Huseyin; Tombus, Fazli Engin] Hitit Univ, Vocat Sch Tech Sci, Dept Survey & Cadastre, Corum, Turkeyen_US
dc.contributor.institutionauthor[Belirlenecek]
dc.identifier.doi10.1080/17452007.2021.1926899
dc.authorwosidSevik, Seyfi / D-4039-2017
dc.description.wospublicationidWOS:000654196400001en_US
dc.description.scopuspublicationid2-s2.0-85106456952en_US