Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorUcer, Mehmet Baris
dc.contributor.authorBozkurt, Erdinc
dc.date.accessioned2021-11-01T15:05:41Z
dc.date.available2021-11-01T15:05:41Z
dc.date.issued2021
dc.identifier.issn2515-8414
dc.identifier.urihttps://doi.org/10.1177/2515841421995633
dc.identifier.urihttps://hdl.handle.net/11491/7372
dc.description.abstractPurpose: The purpose of this study was to compare and evaluate the agreement of central corneal thickness (CCT) values obtained with three different devices working according to optical principle in healthy eyes. Methods: 60 eyes of 60 individuals (30 men and 30 women) were enrolled in this study. CCT measurements performed with Scheimpflug-Placido topographer (Sirius), spectral-domain optical coherence tomography (RTVue) with an anterior segment module, and optical biometer (AL-Scan) were compared. Bland-Altman analysis was used to demonstrate agreement between methods. Results: The mean age was 30.07 +/- 7.313 years (range, 18-47 years). The mean CCT values obtained by RTVue, Sirius, and AL-Scan were 518.25 +/- 36.38 mu m, 526.08 +/- 36.33 mu m, and 513.50 +/- 39.09 mu m, respectively. The mean differences in CCT were 7.83 +/- 14.15 mu m between Sirius and RTVue, 12.58 +/- 11.87 mu m between Sirius and AL-Scan, and 4.75 +/- 4.50 mu m between RTVue and AL-Scan. The mean CCT was statistically different among the three groups (p <0.05). All three modalities of CCT measurements correlated closely with each other, with Pearson's correlation coefficients ranging from 0.924 to 0.961. The 95% limits of agreement were -19.90 to 35.56 mu m between Sirius and RTVue, -10.69 to 35.85 pm between Sirius and AL-Scan, and -4.07 to 13.58 mu m between RTVue and AL-Scan. Conclusion: Different results could be obtained through different noncontact devices in CCT measurements. Although the measurement values obtained by these devices show a high level of correlation, it would be a more correct approach to not use them directly interchangeably in clinical practice. Evaluation and follow-up of CCT should be performed using the same device.en_US
dc.language.isoengen_US
dc.publisherSage Publications Ltden_US
dc.relation.ispartofTherapeutic Advances In Ophthalmologyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAL-Scanen_US
dc.subjectcentral corneal thicknessen_US
dc.subjectpachymetryen_US
dc.subjectRTVueen_US
dc.subjectSiriusen_US
dc.titleComparison of central corneal thickness measurements with three different optical devicesen_US
dc.typearticleen_US
dc.department[Belirlenecek]en_US
dc.authoridUcer, Mehmet Baris / 0000-0002-6807-4909
dc.identifier.volume13en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.department-temp[Ucer, Mehmet Baris] Hitit Univ, Erol Olcok Educ & Res Hosp, Minist Hlth, Dept Ophthalmol,Ophthalmol, TR-19000 Corum, Turkey; [Bozkurt, Erdinc] Kafkas Univ, Fac Med, Dept Ophthalmol, Kars, Turkeyen_US
dc.contributor.institutionauthor[Belirlenecek]
dc.identifier.doi10.1177/2515841421995633
dc.authorwosidUcer, Mehmet Baris / AAB-3242-2020
dc.description.wospublicationidWOS:000623523100001en_US
dc.description.pubmedpublicationidPubMed: 33748670en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster