Acoustic analysis of a liquefied petroleum gas-fired pulse combustor
(2008)
Experimental investigation of acoustic characteristics of a Helmholtz type liquefied petroleum gas-fired pulse combustor is presented. In the experiments, the length of the tail pipe was changed from 1.9 m to 1.3 m by 10 ...
Exergy analysis of R1234yf and R1234ze as R134a replacements in a two evaporator vapour compression refrigeration system
(Elsevier Ltd, 2015)
Exergy analysis is a useful way for determining the real thermodynamic losses and optimising environmental and economic performance in the systems such as vapour compression refrigeration systems. The present study deals ...
Second law analysis of different refrigerants in a two stage vapor compression cycle
(Turkish Society for Thermal Science and Technology, 2015)
In this study, the second law analysis has been made by means of the program developed using the software program EES (EES-V9.172-3D) in a two stage vapor-compression refrigeration cycle for the refrigerants such as R600 ...
Comparison of superheating effect of water as a refrigerant with the other refrigerants
(2011)
The performance comparison of water as a refrigerant (R718) with some refrigerants including R717, R290, R134a, and R152a is presented for a vapor compression refrigeration cycle. A computer program simulating the vapor ...
Irreversibility analysis of a two-evaporator vapour compression refrigeration system
(Inderscience Enterprises Ltd., 2015)
In this study, irreversibility analysis of a two-evaporator vapour compression refrigeration system under the influence of superheating and subcooling effects was carried out. The thermodynamic properties of the refrigerants ...
Investigation of the component exergy efficiencies of a two stage vapour compression cycle
(Inderscience Enterprises Ltd., 2018)
The exergy efficiencies of the components (compressor I and II, condenser, evaporator and flash tank) of a two stage vapour compression refrigeration cycle were analysed with respect to evaporator and condenser temperatures ...
Irreversibility analysis of a compression refrigeration cycle using natural refrigerants for a sustainable future
(2012)
Irreversibility analyses of R290, R717, R718 and R744 are carried out in a compression refrigeration cycle. The effects of evaporator temperature, condenser temperature and isentropic efficiency on the irreversibility of ...
Energy and irreversibility analysis of a cascade refrigeration system for various refrigerant couples
(2010)
This study deals with energy and irreversibility analysis of a cascade refrigeration system employing various refrigerant couples, namely R152a–R23, R290–R23, R507–R23, R234a–R23, R717–R23 and R404a–R23, using a computer ...
Effect of swirl generator inserted into a tube on exergy transfer: Decaying flow
(Taylor and Francis Inc., 2014)
This study experimentally investigates the effect of conical injector type swirl generator inserts on heat and exergy transfer in a uniform heat flux tube for turbulence regime. One hundred twenty watts of heat are applied ...
Assessment of an IGCC based trigeneration system for power, hydrogen and synthesis fuel production
(Elsevier Ltd, 2016)
In this study, an integrated gasification combined cycle based trigeneration system is proposed to produce power, hydrogen and various Fischer-Tropsch (FT) synthesis products. The proposed plant consists of an (a) air ...