    Tribological evaluation of biomedical polycarbonate urethanes against articular cartilage
    (Elsevier Science Bv, 2018) Kanca, Yusuf; Milner, Piers; Dini, Daniele; Amis, Andrew A.
    This research investigated the in-vitro wear and friction performance of polycarbonate urethane (PCU) 80A as they interact with articular cartilage, using a customised multidirectional pin-on-plate tester. Condyles were articulated against PCU 80A discs (Bionate(center dot) I and Bionate(center dot) II) (configuration 1) and the results arising from these tests were compared to those recorded during the sliding of PCU pins against cartilage plates (configuration 2). Configuration 1 produced steadily increasing coefficient of friction (COF) (up to 0.64 +/- 0.05) and had the same trend as the cartilage on stainless steel articulation (positive control). When synovial fluid rather than bovine calf serum was used as lubricant, average COF significantly decreased from 0.50 +/- 0.02-0.38 +/- 0.06 for condyle on Bionate(center dot) I (80AI) and from 0.41 +/- 0.02-0.24 +/- 0.04 for condyle on Bionate(center dot) II (80AII) test configurations (p < 0.05). After 15 h testing, the cartilage on cartilage articulation (negative control) tests showed no cartilage degeneration. However, different levels of cartilage volume loss were found on the condyles from the positive control (12.5 +/- 4.2 mm(3)) and the PCUs (20.1 +/- 3.6 mm(3) for 80 AI and 19.0 +/- 2.3 mm(3) for 80AII) (p > 0.05). A good correlation (R-2 = 0.84) was found between the levels of average COF and the volume of cartilage lost during testing; increasing wear was found at higher levels of COF. Configuration 2 showed low and constant COF values (0.04 +/- 0.01), which were closer to the negative control (0.03 +/- 0.01) and significantly lower than configuration 1 (p < 0.05). The investigation showed that PCU is a good candidate for use in hemiarthroplasty components, where only one of the two articulating surfaces is replaced, as long as the synthetic material is implanted in a region where migrating cartilage contact is achieved. Bionate(center dot) II showed better tribological performance, which suggests it is more favourable for use in hemiarthroplasty design.
  • [ X ]
    Öğe
    Tribological properties of PVA/PVP blend hydrogels against articular cartilage
    (Elsevier Science Bv, 2018) Kanca, Yusuf; Milner, Piers; Dini, Daniele; Amis, Andrew A.
    This research investigated in-vitro tribological performance of the articulation of cartilage-on-polyvinyl alcohol (PVA) and polyvinyl pyrrolidone (PVP) blend hydrogels using a custom-designed multi-directional wear rig. The hydrogels were prepared by repeated freezing-thawing cycles at different concentrations and PVA to PVP fractions at a given concentration. PVA/PVP blend hydrogels showed low coefficient of friction (COF) values (between 0.12 +/- 0.01 and 0.14 +/- 0.02) which were closer to the cartilage-on-cartilage articulation (0.03 +/- 0.01) compared to the cartilage-on-stainless steel articulation (0.46 +/- 0.06). The COF increased with increasing hydrogel concentration (p = 0.03) and decreasing PVP content at a given concentration (p < 0.05). The cartilage-on-hydrogel tests showed only the surface layers of the cartilage being removed (average volume loss of the condyles was 12.5 +/- 4.2 mm(3)). However, the hydrogels were found to be worn/deformed. The hydrogels prepared at a higher concentration showed lower apparent volume loss. A strong correlation (R-2 = 0.94) was found between the COF and compressive moduli of the hydrogel groups, resulting from decreasing contact congruency. It was concluded that the hydrogels were promising as hemiarthroplasty materials, but that improved mechanical behaviour was required for clinical use.

| Hitit Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kütüphane ve Dokümantasyon Daire Başkanlığı, Çorum, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim