Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Kaddour, Samia" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    A Facile Strategy for Construction of Sensor for Detection of Ondansetron and Investigation of its Redox Behavior and Thermodynamic Parameters
    (Wiley-VCH Verlag, 2019) Zaabal, Moufida; Doulache, Merzak; Karadaş Bakırhan, Nurgül; Kaddour, Samia; Saidat, Boubakeur; Özkan, Sibel Ayşıl
    A sodium dodecylsulfate-doped polypyrrole (SDS-PPy) film was elaborated on glassy carbon electrode (GCE) by an electrodeposition method in phosphate buffer solution (pH 2.0) containing pyrrole (Py) and sodium dodecyl sulfate (SDS). SDS-PPy/GCE was used for the construction of sensor, which showed excellent electrochemical response for the detection of ondansetron (OND) compared to conventional PPy. The application of the square wave (SW), with the adsorptive accumulation, indicates a maximum response at 1.33 V in H2SO4 (0.5 M). The influence of experimental parameters on determination of OND is discussed. The adsorptive stripping technique showed to be more sensitive, giving responses twice as big as those of non-accumulated OND. The substantial improvement of response permits the development of an electroanalytical technique with a linear concentration in the range (1.0–80 ?M), low detection (0.09 ?M), and quantification limits (0.3 ?M), and acceptable relative standard deviations of repeatability (0.59 %), and reproducibility (1.51 %). Consequently, this electrode is promising candidate for an accurate electroanalytical determination of OND in pharmaceutical samples with high sensitivity and selectivity, good accuracy and precision. The electrooxidation of OND at SDS-PPy/GCE at various temperatures were studied by cyclic voltammetry to evaluate both the kinetic (ks and Ea) and thermodynamic (?G*, ?H* and ?S*) parameters. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim

| Hitit Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kütüphane ve Dokümantasyon Daire Başkanlığı, Çorum, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim