Comparison of Six Methods of Central Corneal Thickness Measurement in Healthy Eyes

dc.contributor.authorİçel, Erel
dc.contributor.authorKarakurt, Yücel
dc.contributor.authorYılmaz, Hayati
dc.contributor.authorUğurlu, Adem
dc.contributor.authorDemir, Mehmet
dc.date.accessioned2021-11-01T18:19:13Z
dc.date.available2021-11-01T18:19:13Z
dc.date.issued2021
dc.departmentHitit Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü
dc.description.abstractObjectives: Several methods of measuring central corneal thickness (CCT) have been compared, however, the data are still limited and conflicting. The aim of this study was to determine the agreement of CCT measurements performed in healthy eyes using ultrasound pachymetry (USP), non-contact tono/pachymetry, specular microscopy, biometry, Scheimpflug-based corneal topography, and optical coherence tomography (OCT). Methods: All of the participants underwent a complete ophthalmological examination. The CCT of all of the eyes included was measured using 6 different methods. The agreement between the methods was analyzed using the mean difference and Bland-Altman analysis based on a 95% limits of agreement. Results: A total of 64 patients with a mean age of 40.96±14.52 years (range: 20-78 years) were included in the study. The mean CCT value was 552.10±35.65 ?m, 550.40±35.55 ?m, 554.67±35.49 ?m, 545.39±34.21 ?m, 546.25±35.49 ?m, and 552.64±33.59 ?m using USP, non-contact tono/pachymetry, non-contact specular microscopy, biometry, Scheimpflugbased corneal topography, and OCT, respectively. The bias values determined by Bland-Altman plots were -1.70, -2.56, 6.71, 5.85, and -0.53 for tono/pachymetry, specular microscopy, biometry, topography, and OCT, respectively. OCT demonstrated the lowest bias compared to USP. The overall intraclass correlation coefficient was 0.961 (range: 0.945- 0.974) with a 95% confidence interval. Conclusion: All of the CCT measurements obtained using non-contact tono/pachymetry, non-contact specular microscopy, biometry, Scheimpflug-based corneal topography, and OCT were consistent with the USP measurements of healthy controls. Larger prospective studies to determine the interchangeability of different methods for CCT measurements in pathological conditions are warranted.
dc.identifier.citationUcak, T., Icel, E., Tasli, N. G., Karakurt, Y., Yilmaz, H., Ugurlu, A., & Demir, M. (2021). Comparison of Six Methods of Central Corneal Thickness Measurement in Healthy Eyes. Beyoglu Eye Journal, 6(1), 7.
dc.identifier.doi10.14744/bej.2021.17894
dc.identifier.endpage13en_US
dc.identifier.issn2459-1777
dc.identifier.issn2587-0394
dc.identifier.issue1en_US
dc.identifier.startpage7en_US
dc.identifier.urihttps://doi.org10.14744/bej.2021.17894
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TkRJM05ESTRPQT09
dc.identifier.urihttps://hdl.handle.net/11491/8309
dc.identifier.volume6en_US
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorYılmaz, Hayati
dc.language.isoen
dc.relation.ispartofBEYOGLU EYE JOURNAL
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBiometryen_US
dc.subjectCentral corneal thicknessen_US
dc.subjectCorneal topographyen_US
dc.subjectPachymetryen_US
dc.subjectSpecular microscopyen_US
dc.titleComparison of Six Methods of Central Corneal Thickness Measurement in Healthy Eyes
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
hayati-yilmaz2021.pdf
Boyut:
270.2 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text