Energy and exergy analysis of an air conditioning system using the mixture of outdoor and return air

dc.authorid0000-0003-1340-1893
dc.authorid0000-0002-3720-8353
dc.contributor.authorKılıçarslan, Ali
dc.contributor.authorKurtbaş, İrfan
dc.date.accessioned2019-05-13T09:08:54Z
dc.date.available2019-05-13T09:08:54Z
dc.date.issued2012
dc.departmentHitit Üniversitesi, Mühendislik Fakültesi, Makine Mühendisliği Bölümü
dc.descriptionASME 2012 International Mechanical Engineering Congress and Exposition, IMECE 2012, 9 November 2012 through 15 November 2012, Houston, TX
dc.description.abstractEnergy and exergy analysis of the air conditioning systems employing the mixture of outdoor and return air (ACOR) are presented. The equations of heat transfer rate and exergy destruction are developed for ACOR according to the system parameters of moist air and condensate water. The effects of the incoming air dry bulb temperature to the coil and relative humidity, and leaving air dry bulb temperature from the coil on the heat transfer and exergy destruction are investigated by means of a computer code developed. The heat transfer from the air to the coil increased as the incoming air dry bulb temperature and relative humidity increased while the heat transfer decreased with the increase in the leaving air dry bulb temperature. The exergy destruction of the moist air increased as the incoming air dry bulb temperature increased, but it decreased with the increasing values of incoming air relative humidity values. Copyright © 2012 by ASME.
dc.identifier.citationKılıçarslan, A., Kurtbaş, İ. (2013, October). Energy and exergy Analysis of an air conditioning system using the mixture of outdoor and return air. ASME 2012 International Mechanical Engineering Congress and Exposition, November 9–15, 2012, Houston, Texas, USA.
dc.identifier.doi10.1115/IMECE2012-89110
dc.identifier.endpage1048en_US
dc.identifier.isbn9780791845226
dc.identifier.issuePARTS A AND Ben_US
dc.identifier.scopusqualityN/A
dc.identifier.startpage1041en_US
dc.identifier.urihttps://doi.org/10.1115/IMECE2012-89110
dc.identifier.urihttps://hdl.handle.net/11491/2071
dc.identifier.volume6en_US
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.relation.ispartofASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAir Conditioningen_US
dc.subjectCoolingen_US
dc.subjectEnergyen_US
dc.subjectExergyen_US
dc.subjectExergy Destructionen_US
dc.titleEnergy and exergy analysis of an air conditioning system using the mixture of outdoor and return air