Irreversibility analysis of a two-evaporator vapour compression refrigeration system

dc.authorid0000-0002-3720-8353
dc.contributor.authorYatağanbaba, Alptuğ
dc.contributor.authorKılıçarslan, Ali
dc.contributor.authorKurtbaş, İrfan
dc.date.accessioned2019-05-13T09:07:04Z
dc.date.available2019-05-13T09:07:04Z
dc.date.issued2015
dc.departmentHitit Üniversitesi, Mühendislik Fakültesi, Makine Mühendisliği Bölümü
dc.description.abstractIn this study, irreversibility analysis of a two-evaporator vapour compression refrigeration system under the influence of superheating and subcooling effects was carried out. The thermodynamic properties of the refrigerants were formulated using the most commonly used software Engineering Equation Solver (EES-V9.172-3D) in the analysis of refrigeration systems. Environment friendly refrigerants R407C, R410A, R404A and R134a were taken into consideration and the analysis was based on the second law of thermodynamics. The effect of the evaporator and condenser temperature on the irreversibility of the system components, such as evaporator, compressor and condenser were investigated. In addition to this, the exergy efficiency values of the system components were computed in accordance with refrigerants in terms of a certain operating conditions. One of the more significant findings to emerge from this study is that irreversibility values of system components depend on evaporator and condenser temperature change. © 2015 Inderscience Enterprises Ltd.
dc.identifier.citationYatağanbaba, A., Kılıçarslan, A., Kurtbaş, İ. (2015). Irreversibility analysis of a two-evaporator vapour compression refrigeration system. International Journal of Exergy, 18(3), 340-355.
dc.identifier.doi10.1504/IJEX.2015.072895
dc.identifier.endpage355en_US
dc.identifier.issn1742-8297
dc.identifier.issue3en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage340en_US
dc.identifier.urihttps://doi.org/10.1504/IJEX.2015.072895
dc.identifier.urihttps://hdl.handle.net/11491/1716
dc.identifier.volume18en_US
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherInderscience Enterprises Ltd.
dc.relation.ispartofInternational Journal of Exergy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectExergy Efficiencyen_US
dc.subjectIrreversibilityen_US
dc.subjectTwo Evaporatorsen_US
dc.subjectVapour Compressionen_US
dc.titleIrreversibility analysis of a two-evaporator vapour compression refrigeration system
dc.typeArticle

Dosyalar