dc.description2016 International Conference on Optoelectronics and Image Processing, ICOIP 2016, 10 June 2016 through 12 June 2016,
dc.description.abstractDiagnostic ultrasounds transmit sound waves into the body, and thus reveal important information about it. Because the transmitted sound waves cause tissue heating, diagnostic ultrasounds can produce adverse biologic effects in tissue, namely, thermal bioeffect. Both tissue characters and ultrasound parameters affect the amount of temperature rise on the tissue. Program Spheresum [1] gives the temperature rise on the tissue scanned by a diagnostic ultrasound. This study compares tissue temperature rise due to linear array transducers with different parameters by using Spheresum. The results show that the maximum temperature rise is generally near the source surface in the linear array transducer application with high frequency for different focal points. Especially in tissue with a high absorption coefficient and for the linear array transducer with high frequency, tissue temperature rise near the source surface should be considered as the image resolution. © 2016 IEEE.
dc.identifier.citationGüngör, M. A., Karagöz, İ. (2016, June). The analysis of tissue temperature rise caused by linear array transducers with Program Spheresum. 2016 International Conference on Optoelectronics and Image Processing (ICOIP), Warsaw, Poland.
dc.identifier.doi10.1109/OPTIP.2016.7528519
dc.identifier.endpage58en_US
dc.identifier.isbn9781509008797
dc.identifier.scopusqualityN/A
dc.identifier.startpage54en_US
dc.identifier.urihttps://doi.org/10.1109/OPTIP.2016.7528519
dc.identifier.urihttps://hdl.handle.net/11491/2081
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.ispartofProceedings - 2016 International Conference on Optoelectronics and Image Processing, ICOIP 2016
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDiagnostic Ultrasounden_US
dc.subjectTemperature Riseen_US
dc.subjectUltrasound Parametersen_US
dc.titleThe analysis of tissue temperature rise caused by linear array transducers with Program Spheresum
dc.typeConference Object

Dosyalar