Electrochemical evaluation and determination of antiretroviral drug fosamprenavir using boron-doped diamond and glassy carbon electrodes

dc.contributor.authorGümüştaş, Mehmet
dc.contributor.authorÖzkan, Sibel Ayşıl
dc.date.accessioned2019-05-13T09:06:53Z
dc.date.available2019-05-13T09:06:53Z
dc.date.issued2010
dc.departmentHitit Üniversitesi, Fen Edebiyat Fakültesi, Kimya Bölümü
dc.description.abstractFosamprenavir is a pro-drug of the antiretroviral protease inhibitor amprenavir and is oxidizable at solid electrodes. The anodic oxidation behavior of fosamprenavir was investigated using cyclic and linear sweep voltammetry at boron-doped diamond and glassy carbon electrodes. In cyclic voltammetry, depending on pH values, fosamprenavir showed one sharp irreversible oxidation peak or wave depending on the working electrode. The mechanism of the oxidation process was discussed. The voltammetric study of some model compounds allowed elucidation of the possible oxidation mechanism of fosamprenavir. The aim of this study was to determine fosamprenavir levels in pharmaceutical formulations and biological samples by means of electrochemical methods. Using the sharp oxidation response, two voltammetric methods were described for the determination of fosamprenavir by differential pulse and square-wave voltammetry at the boron-doped diamond and glassy carbon electrodes. These two voltammetric techniques are 0.1 M H2SO4 and phosphate buffer at pH 2.0 which allow quantitation over a 4×10-6 to 8×10 -5 M range using boron-doped diamond and a 1×10-5 to 1×10-4 M range using glassy carbon electrodes, respectively, in supporting electrolyte. All necessary validation parameters were investigated and calculated. These methods were successfully applied for the analysis of fosamprenavir pharmaceutical dosage forms, human serum and urine samples. The standard addition method was used in biological media using boron-doped diamond electrode. No electroactive interferences from the tablet excipients or endogenous substances from biological material were found. The results were statistically compared with those obtained through an established HPLC-UV technique; no significant differences were found between the voltammetric and HPLC methods. © 2009 Springer-Verlag.
dc.identifier.citationGumustas, M., & Ozkan, S. A. (2010). Electrochemical evaluation and determination of antiretroviral drug fosamprenavir using boron-doped diamond and glassy carbon electrodes. Analytical and bioanalytical chemistry, 397(1), 189-203.
dc.identifier.doi10.1007/s00216-009-3334-3
dc.identifier.endpage203en_US
dc.identifier.issn1618-2642
dc.identifier.issue1en_US
dc.identifier.scopusqualityQ1
dc.identifier.startpage189en_US
dc.identifier.urihttps://doi.org/10.1007/s00216-009-3334-3
dc.identifier.urihttps://hdl.handle.net/11491/1674
dc.identifier.volume397en_US
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.relation.ispartofAnalytical and Bioanalytical Chemistry
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBoron-Doped Diamonden_US
dc.subjectDeterminationen_US
dc.subjectFosamprenaviren_US
dc.subjectGlassy Carbonen_US
dc.subjectOxidation Mechanismen_US
dc.subjectVoltammetryen_US
dc.titleElectrochemical evaluation and determination of antiretroviral drug fosamprenavir using boron-doped diamond and glassy carbon electrodes
dc.typeConference Object

Dosyalar