Diagnostic utility of the sonographic median to ulnar nerve cross-sectional area ratio in carpal tunnel syndrome
dc.contributor.author | Atan, Tuğba | |
dc.contributor.author | Günendi, Zafer | |
dc.date.accessioned | 2019-05-13T09:02:44Z | |
dc.date.available | 2019-05-13T09:02:44Z | |
dc.date.issued | 2018 | |
dc.department | Hitit Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü | |
dc.description.abstract | Background/aim: The aim of this study was to assess the diagnostic utility of the ultrasonographic ratio of median nerve cross-sectional area (m-CSA) to ulnar nerve cross-sectional area (u-CSA), the m-CSA/u-CSA ratio, in carpal tunnel syndrome (CTS). Materials and methods: Fifty patients with positive symptoms and electromyography results of CTS and 50 healthy matched control subjects were evaluated. Ultrasonographic m-CSA and u-CSA measurements of each participant were made at the level of the pisiform bone and the m-CSA/u-CSA ratio was calculated. Results: Using the m-CSA cut-off value of 11.95 mm2 showed a sensitivity of 80% and a specificity of 80% while using a cut-off value 2.95 for the ratio of m-CSA/u-CSA showed a sensitivity of 86% and a specificity of 72% in the diagnosis of CTS. Conclusion: The ratio of m-CSA/u-CSA at the level of the pisiform bone was not detected to be superior to m-CSA in the diagnosis of CTS. © TÜBİTAK. | |
dc.identifier.citation | Atan, T., Günendi, Z. (2018). Diagnostic utility of the sonographic median to ulnar nerve cross-sectional area ratio in carpal tunnel syndrome. Turkish Journal of Medical Sciences, 48(1), 110-116. | |
dc.identifier.doi | 10.3906/sag-1707-124 | |
dc.identifier.endpage | 116 | en_US |
dc.identifier.issn | 1300-0144 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 110 | en_US |
dc.identifier.uri | https://doi.org/10.3906/sag-1707-124 | |
dc.identifier.uri | https://hdl.handle.net/11491/1319 | |
dc.identifier.volume | 48 | en_US |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | TÜBİTAK | |
dc.relation.ispartof | Turkish Journal of Medical Sciences | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Carpal Tunnel Syndrome | en_US |
dc.subject | Cross-Sectional Area | en_US |
dc.subject | Ratio | en_US |
dc.subject | Ulnar Nerve | en_US |
dc.subject | Ultrasonography | en_US |
dc.title | Diagnostic utility of the sonographic median to ulnar nerve cross-sectional area ratio in carpal tunnel syndrome | |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- atantugba.pdf
- Boyut:
- 462.43 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text