Relationship between internal carotid artery stenosis grade and optic nerve sheath diameter measured by transorbital ultrasonography
[ X ]
Tarih
2021
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Wiley
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Purpose To assess the consequence of the presence, grade, and asymmetry of carotid artery stenoses on the optic nerve sheath diameter (ONSD) measured by ultrasonography. Methods ONSD was measured with B-mode ultrasonography in 129 patients referred for duplex and color Doppler imaging of the carotid arteries. Internal carotid artery stenosis was graded on the basis of peak systolic flow velocity. Results The mean ONSD was 3.04 +/- 0.38 mm in the patients without or with 70% stenosis. There was an average difference of 0.58 mm between the ONSD of the patients with 70% stenosis. Conclusion ONSD is lower in patients with carotid artery stenosis. Carotid arteries should be investigated, especially in patients with cardiovascular risk factors or diseases, before interpreting ONSD values.
Açıklama
Anahtar Kelimeler
carotid stenosis, optic nerve, ultrasonography
Kaynak
Journal Of Clinical Ultrasound
WoS Q Değeri
Q4
Scopus Q Değeri
Q3
Cilt
49
Sayı
7