Comparison of radiological and functional results in osteoporotic distal femur fractures operated with single plating, lateral incision, and double plating, anterior paramedial incision: A retrospective study

dc.authorid0000-0001-5654-9500
dc.contributor.authorÇalbıyık, Murat
dc.contributor.authorZehir, Sinan
dc.contributor.authorDemirezen, Murat Okan
dc.date.accessioned2024-07-30T08:21:49Z
dc.date.available2024-07-30T08:21:49Z
dc.date.issued2024en_US
dc.departmentHitit Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü
dc.description.abstractTreatment of osteoporotic distal femur fractures is often complicated by a high rate of nonunion and varus collapse. For such fractures, lateral plating with lateral incision and double plating with anterior paramedial incision have shown promising results in the recent literature. The hypothesis of this study was that bilateral plating of comminuted distal femur fractures in osteoporotic patients would result in higher union rates and lower revision rates compared to an isolated lateral locking plate. The study included 56 patients (23 males, 33 females) with supracondylar femur fracture. According to the OA/OTA classification, 9 were type A3, 8 were A2, 13 were C1, 16 were C2, and 10 were C3. The mean follow-up period was 12 months, with 29 patients treated using lateral mini-incision, lateral locking plate, and 27 patients treated with anterior paramedial incision, dual plating. The clinical and radiological results were evaluated. The mean duration of radiological union in the studied population was 15 +/- 2.1 months (range, 11-21 months) in the single plate group (Group A), and 13.5 +/- 2.6 months (range, 9-19 months) in the double plate group (Group B). Mean ROM was 112.3 degrees and flexion contracture 4 degrees in Group A, and ROM 108.3 degrees and flexion contracture 6.7 degrees in Group B. (P = .15). The average Western Ontario and McMaster Universities Arthritis Index (WOMAC) score was 85.6 points in Group A and 83.5 points in Group B (P = .2278). The postoperative anteversion measurement in the operated extremity ranged from -15 to 19 in Group A, and from 5 to 18 in Group B. When the anteversion degrees were compared between the injured and uninjured extremities in the postoperative period, a significant difference was observed within Group A (P = .0018), but no significant difference was observed in Group B (P = .2492). Dual plate fixation using the anterior paramedial approach is an effective operative method for osteoporotic distal femur fractures. This has many advantages such as precise exposure, easy manipulation, anatomic reduction, and stable fixation. However, for surgical indications and medial bone defects > 1 cm, grafting should be performed.
dc.description.provenanceSubmitted by Zeynep Umut NARİN (umutarslan@hitit.edu.tr) on 2024-07-30T08:20:54Z No. of bitstreams: 1 murat-calbiyik2024.pdf: 903166 bytes, checksum: 0e60e58aa7ef7e1f19482c29d96c285a (MD5)en
dc.description.provenanceApproved for entry into archive by Zeynep Umut NARİN (umutarslan@hitit.edu.tr) on 2024-07-30T08:21:48Z (GMT) No. of bitstreams: 1 murat-calbiyik2024.pdf: 903166 bytes, checksum: 0e60e58aa7ef7e1f19482c29d96c285a (MD5)en
dc.description.provenanceMade available in DSpace on 2024-07-30T08:21:49Z (GMT). No. of bitstreams: 1 murat-calbiyik2024.pdf: 903166 bytes, checksum: 0e60e58aa7ef7e1f19482c29d96c285a (MD5) Previous issue date: 2024en
dc.identifier.citationÇalbiyik, M., Zehir, S., & Demirezen, M. O. (2024). Comparison of radiological and functional results in osteoporotic distal femur fractures operated with single plating, lateral incision, and double plating, anterior paramedial incision: A retrospective study. Medicine, 103(5).
dc.identifier.doi10.1097/MD.0000000000036904
dc.identifier.issn1536-5964
dc.identifier.issn0025-7974
dc.identifier.pmid38306559
dc.identifier.scopusqualityQ2
dc.identifier.urihttp://dx.doi.org/10.1097/MD.0000000000036904
dc.identifier.urihttps://hdl.handle.net/11491/9042
dc.identifier.wosWOS:001156361800069
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorÇalbıyık, Murat
dc.institutionauthorZehir, Sinan
dc.institutionauthorDemirezen, Murat Okan
dc.language.isoen
dc.publisherLIPPINCOTT WILLIAMS & WILKINS
dc.relation.ispartofMEDICINE
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDistal femuren_US
dc.subjectDual locking plateen_US
dc.subjectFracturesen_US
dc.subjectOsteoporoticen_US
dc.titleComparison of radiological and functional results in osteoporotic distal femur fractures operated with single plating, lateral incision, and double plating, anterior paramedial incision: A retrospective study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
murat-calbiyik2024.pdf
Boyut:
882 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: