A novel suture technique for distal aorta-graft anastomosis in aortic aneurysm repair surgery: Diagonal basting stitch
[ X ]
Tarih
2015
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Elsevier Inc.
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
We describe a novel suture technique of distal anastomosis between the graft and the aorta in ascending aortic aneurysm repair surgery. In this technique, the aortic graft is positioned inside the distal aortic lumen with an overlapping segment and circumferential or back wall part only diagonal basting stitches are performed without use of Teflon pledgets, strips, or bioadhesives. This new technique establishes a secure anastomosis line, shortens anastomosis time, and avoids the use of foreign materials. © 2015 Elsevier Inc.
Açıklama
Anahtar Kelimeler
[Belirlenecek]
Kaynak
Annals of Vascular Surgery
WoS Q Değeri
N/A
Scopus Q Değeri
Q2
Cilt
29
Sayı
4
Künye
Çağlı, K., Çiçek, Ö. F., Lafçı, G. (2015). A novel suture technique for distal aorta-graft anastomosis in aortic aneurysm repair surgery: Diagonal basting stitch. Annals of Vascular Surgery, 29(4), 864-867.