Validation of the ActiGraph wGT3X-BT Accelerometer for Step Counts at Five Different Body Locations in Laboratory Settings

dc.contributor.authorKaraca, Ayda
dc.contributor.authorDemirci, Necip
dc.contributor.authorYılmaz, Vedat
dc.contributor.authorHazır Aytar, Sinem
dc.contributor.authorCan, Sema
dc.contributor.authorÜnver, Evrim
dc.date.accessioned2021-11-01T15:05:52Z
dc.date.available2021-11-01T15:05:52Z
dc.date.issued2021
dc.departmentHitit Üniversitesi, Spor Bilimleri Fakültesi, Antrenörlük Eğitimi Bölümü
dc.description.abstractThis study aimed to determine the validity of the ActiGraph wGT3X-BT for step counts (SC) at five different body locations in laboratory settings. A total of 29 male adults participated in this study. The participants walked or ran for different speeds on the treadmill while wearing ActiGraph wGT3X-BT on their right wrist (RW), left wrist (LW), waist, right ankle (RA), and right upper arm (RUA). Both the video camera and each ActiGraph recorded SC simultaneously. The waist, RUA (6, 8, 10 km/hr and total), and RA (4 and 6 km/hr) showed small Mean Absolute Percentage Error (MAPE) values (<5%) and good agreement with Bland-Altman plots. However, the waist (2 and 4 km/hr), RUA (2 and 4 km/hr), RA (2, 8, 10 km/hr and total), RW, and LW showed high MAPE. In conclusion, the waist and RUA are valid for the total SC during walking and running in the laboratory setting.
dc.identifier.citationKaraca, A., Demirci, N., Yılmaz, V., Hazır Aytar, S., Can, S., & Ünver, E. (2021). Validation of the ActiGraph wGT3X-BT Accelerometer for Step Counts at Five Different Body Locations in Laboratory Settings. Measurement in Physical Education and Exercise Science, 1-10.
dc.identifier.doi10.1080/1091367X.2021.1948414
dc.identifier.issn1091-367X
dc.identifier.issn1532-7841
dc.identifier.scopus2-s2.0-85109397444
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1080/1091367X.2021.1948414
dc.identifier.urihttps://hdl.handle.net/11491/7425
dc.identifier.wosWOS:000669123800001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorCan, Sema
dc.language.isoen
dc.publisherRoutledge Journals, Taylor & Francis Ltd
dc.relation.ispartofMeasurement In Physical Education And Exercise Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectValidityen_US
dc.subjectActiGraph wGT3X-BTen_US
dc.subjectDifferent Body Locationsen_US
dc.subjectDifferent Speedsen_US
dc.titleValidation of the ActiGraph wGT3X-BT Accelerometer for Step Counts at Five Different Body Locations in Laboratory Settings
dc.typeArticle

Dosyalar