Characteristic localization patterns of thrombus on various brands of bileaflet mitral mechanical heart valves as assessed by three-dimensional transesophageal echocardiography and their relationship with thromboembolism

dc.authoridSarı, Munevver / 0000-0003-2061-415X
dc.authoridKalkan, Semih / 0000-0002-1107-0296
dc.authoridKalçık, Macit / 0000-0002-8791-4475
dc.authoridBayram, Zübeyde / 0000-0003-4546-1452
dc.authoridGündüz, Sabahattin / 0000-0003-0704-5335
dc.authoridAytürk, Mehmet / 0000-0003-1088-4172
dc.contributor.authorSarı, Munevver
dc.contributor.authorBayram, Zübeyde
dc.contributor.authorAytürk, Mehmet
dc.contributor.authorBayam, Emrah
dc.contributor.authorKalkan, Semih
dc.contributor.authorGüner, Ahmet
dc.contributor.authorÖzkan, Mehmet
dc.contributor.authorKalçık, Macit
dc.contributor.authorGürsoy, Mustafa Ozan
dc.contributor.authorGündüz, Sabahattin
dc.date.accessioned2021-11-01T15:06:10Z
dc.date.available2021-11-01T15:06:10Z
dc.date.issued2021
dc.departmentHitit Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü
dc.description.abstractThree-dimensional transesophageal echocardiography (3D-TEE) provides detailed images of prosthetic valve thrombosis (PVT). However, data regarding PVT localization patterns based on 3D-TEE and their association with clinical findings among various bileaflet mitral prosthetic valve brands is lacking. The locations of thrombi were classified into 4 groups according to hinge and annulus involvement based on 3D-TEE: ring-like PVT involving entire mitral annulus (type-1), PVT involving peri-hinge(s) region and extends through some part of the annulus (type-2), PVT involving mitral annulus without involving hinge(s) region (type-3), and PVT involving only (peri)hinge(s) area (type-4). This study was conducted in 265 patients (male: 71, mean age: 46.3 +/- 12.7 years) with mitral PVT, including 150 St Jude Medical (SJM), 65 Carbomedics, 29 Medtronic ATS open-pivot, and 21 Sorin bileaflet mechanical valves. There was a significant difference in most common PVT localization patterns between different prosthetic valves (type-1 for Carbomedics and Sorin; type-2 for SJM and type-3 for ATS valves; p < 0.001). Additionally, PVT involving only (peri)hinge region(s) (type-4) was mostly observed in patients with SJM valves (18%). (Peri)hinge(s) area involvement was observed in the majority of study patients (78.1%). In patients who presented with thromboembolism, the most common PVT localization pattern was type-1 (53%). Increased age, low international normalized ratio on admission, PVT with a mobile part > 2 mm, type-1 and type-4 PVT were associated with thromboembolic events. In conclusion, thrombus can be displayed in distinct locations in several types of bileaflet mechanical valves due to different design, hinge and pivot mechanisms, which can be complicated with thromboembolic events.
dc.identifier.citationSari, M., Bayram, Z., Ayturk, M., Bayam, E., Kalkan, S., Guner, A., ... & Ozkan, M. (2021). Characteristic localization patterns of thrombus on various brands of bileaflet mitral mechanical heart valves as assessed by three-dimensional transesophageal echocardiography and their relationship with thromboembolism. The International Journal of Cardiovascular Imaging, 1-15.
dc.identifier.doi10.1007/s10554-021-02234-y
dc.identifier.endpage2705en_US
dc.identifier.issn1569-5794
dc.identifier.issn1573-0743
dc.identifier.issue9en_US
dc.identifier.pmid33835319
dc.identifier.scopus2-s2.0-85104240753
dc.identifier.scopusqualityQ2
dc.identifier.startpage2691en_US
dc.identifier.urihttps://doi.org/10.1007/s10554-021-02234-y
dc.identifier.urihttps://hdl.handle.net/11491/7509
dc.identifier.volume37en_US
dc.identifier.wosWOS:000638473800001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorKalçık, Macit
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofInternational Journal Of Cardiovascular Imaging
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectMitral Valveen_US
dc.subjectProsthetic Valve Thrombosisen_US
dc.subjectTwo-dimensional Transesophageal Echocardiographyen_US
dc.subjectThree-dimensional Transesophageal Echocardiographyen_US
dc.titleCharacteristic localization patterns of thrombus on various brands of bileaflet mitral mechanical heart valves as assessed by three-dimensional transesophageal echocardiography and their relationship with thromboembolism
dc.typeArticle

Dosyalar